Main Page/PHYS 4210/Bell's Inequalities

From Physics Wiki
Revision as of 12:27, 29 January 2014 by Mgeorge (talk | contribs)
Jump to navigation Jump to search

Bell's Inequalities and Quantum Entanglement

Deep at the root of the underlying principles of quantum mechanics lies shadowy principles based on probability which never sit well with some people. This experiment is meant to shine some (laser)light on these principles, and see if we can't come to some deeper understanding of the underlying framework of Quantum Dynamics.

No better introduction can be given than the following set of famous papers, commonly referred to today by their author lists.

  • Einstein, Podolsky, Rosen[1]
  • Bell[2]
  • CHSH (Clauser, Horne, Shimony, & Holt)[3]

It is imperative that you read and understand these papers before you attempt to perform this experiment.

Another useful resource, more directly relevant to the experiment you will be performing is from Dehlinger and Mitchell [4].

Key Concepts

  • Entanglement
  • Parametric down conversion
  • Nonlocality
  • Coincidence
  • Correlation
  • Logic Analyzer
  • Avalanche Photodiode

Method

All optical components have to be precisely aligned in order for your data to yield the expected results. Please take time to understand fully what is described below, and to diligently follow the directions.

Laser Safety goggles are provided, and are mandatory to be worn when the laser is on. THERE ARE NO EXCEPTIONS. If you are noticed not wearing the goggles, you will be forbidden from continuing.

Question: What is the relative sensitivity of the human eye to 405nm?

BE-LaserRegion.png

Figure 1 - Laser Region (Top View).

BE-MainRegion.png

Figure 1 - Experiment setup (Top View).

Step 1: Align the laser and BBO crystal

  1. Remove the mounts containing the half-wave plate, quarter-wave plate and BBO crystal.
  2. Put on your safety goggles, and turn on the 405nm laser by plugging in the power supply. Using the two mirrors, adjust the path of the beam to follow at a constant height and consistently directly about one line of holes in the optics table.
  3. Insert the BBO crystal into position above the vertex of the rails. Adjust the mounting so the laser is passing through the crsytal without clipping. Fine adjust the angle of the crystal so the retro-reflected beam off of the face of the crystal is directly back onto the incoming beam.
  4. Shut off the laser.

Step 2: Align the 810nm-photon collection optics

  1. For detector assembly A, remove the linear polarizer and unscrew the 810nm filter from the front of the photon collection optics.
  2. BE-RemovePolarizer1.png

    Figure 2a - Remove Linear Polarizer.

    BE-RemovePolarizer2.png

    Figure 2b - Remove Linear Polarizer.

    BE-Remove810Filter1.png

    Figure 2c -Unscrew 810nm Filter.

    BE-Remove810Filter2.png

    Figure 2d -Filter and Polarizer Removed.

  3. Adjust (if necessary) the height of the detector assembly to be the same height as the 405nm laser beam.
  4. Adjust the angle of rail containing the detector assembly to he 3 degrees.
  5. Remove the optical fiber attached to the single photon detector corresponding to that detector assembly. Attach the Fiber Checker to this free end of the optical fiber. This will send a beam of read light backwards through the system.
  6. Adjust the mount of the detector assembly so the red beam is aligned onto the back of the BBO crystal.
  7. Replace the 810nm filter, linear polarizer, and fiber connection to the single photon detector.
  8. Repeat above for detector assembly B.

Step 3: Align the waveplates

Step 4: Fine Adjust

Step 5: Take Data!


Core Experiment

To setup the experiment as described in the methods sections and to take one complete set of data required to test Bell's Inequality as described in [4] using the readings from the ratemeter. A full analysis of the data with proper treatment of uncertainties is required.


You are required to complete the core experiment along with your choice of one of the modules listed below.

Module 1: Purity of Correlation

In this module, you will try to improve on the purity of the correlation by reducing the acceptance angle of the single-photon detectors by place adjustable collimating slits into each path before the single photon detectors.

Module 2: Computer Analysis

In this module, you will use a Logic Analyzer to collect the raw outputs from the individual single photon detectors, then create an analysis program to calculate coincidence. Once this is accomplished, you can take data for longer periods of time and reduce the statistical uncertainties.

Module 3: Pump Laser Power

In this module, you will vary the power of the 405nm pump laser beam using neutral density filters in order to study the rate of coincident photon as a function of pump laser power. Does this trend follow expectations?



References

  1. A. Einstein, B. Podolsky & N. Rosen, "Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?" Phys. Rev., 47, 777-780 (1935)
  2. J.S. Bell, "On the Einstein Podolsky Rosen Paradox" Physics, 1, 195 (1964)
  3. J.F. Clauser, M.A. Horne, A. Shimony, & R.A. Holt, "Proposed Experiment to Test Local Hidden-Variable Theories" Phys. Rev. Lett., 23, 880 (1969)
  4. 4.0 4.1 D. Dehlinger & M.W. Mitchell "Entangled photons, nonlocality and Bell inequalities in the undergraduate laboratory." Am. J. Phys. 70, 903 (2002)